  • 2-wire compact transmitter with HART protcol
    Rod or cable probes up to 20 m
    Fully or partly insulated probes
    Secondary lightning protection
    32 point linearisation
    High sensitivity
    Aluminium or plastic housing
    Explosionproof models
  • Tags: Bàn Map
Đơn vị tiền tệ
  • Số lượng:
  • Thành tiền

FEATURES

  • 2-wire compact transmitter with HART protcol
  • Rod or cable probes up to 20 m
  • Fully or partly insulated probes
  • Secondary lightning protection
  • 32 point linearisation
  • High sensitivity
  • Aluminium or plastic housing
  • Explosionproof models


APPLICATIONS

  • Liquids, powders, granules with Er>1.5 relative dielectric constant
  • Chemicals with dense gas layers above the surface
  • Viscose or corrosive mediums
  • High pressure, high temperature or vacuum


SPECIFICATIONS

  • Power supply: 12-36 VDC
  • Ambient temperature: - 25°C to +70°C
  • Medium temperature: - 30°C to +200°C
  • Pressure: max. 40 bar
  • Output: 4-20 mA, HART
  • Process connection: 1'' or 1 1/2'' or flanges
  • Protection: IP67
  • ATEX approval: II 1 G EEx ia IIB T6

 

FEATURES :

  • Output versions:2-wire compact transmitter with 4…20 mA output and optional HART communication
  • Adjustment, programming:Push button, field programmable through optional local display/programmer module, remote HART programming
  • Mounting:On top of the tank. The rod or cable probe are immersed into the medium to be measured. The instrument should be ordered with the required probe length
  • Housing material:Plastic (PBT) or Aluminium cast
  • Material of wetted parts:Stainless steel, FEP
  • Operating principle:Level, volume and weight measurement calculated from the change of the capacitance as the level changes.
  • Ex approval:Yes
  • Protections:EMC certificate EN 61326-1:2007

APPLICATION CONSIDERATIONS :

  • Suggested applications:Standalone installation to metal tanks, if tank is not conductive the use of a reference probe is needed
  • Measurable mediums:Homogenic, electrically conductive liquids or non-conductive (liquids, free-flowing solids) materials with min. ε>1.5 dielectric constant
  • Advantages:The cheapest solution for measuring mediums with high pressure and temperature
  • Special applications:High pressure, high temperature applications
  • Application restrictions:A change in liquid composition or in humidity of the solids may result in decreased accuracy. Conductive deposits on the probe may lead to false measurements.

TECHNICAL DATA :

  • Power supply:12…36 V DC
  • Ambient temperature:-25…+70°C
  • Medium temperature:-30…+200°C
  • Process pressure:Max 40 bar
  • Measuring range:Max 20 m
  • Accuracy:±0.3 %
  • Output:4…20 mA / HART
  • Process connection:1”, 1½”.BSP / NPT thread, flange
  • Ingress protection:IP67
  • Ex marking:Ex II 1 G EEx ia IIB T6

 