SPECIFICATIONS
MODELS 3176B & 3176B1 LIVM ACCELEROMETERS
SPECIFICATION (Common to both models)
PHYSICAL
WEIGHT
SIZE, HEX x HEIGHT
MOUNTING PROVISION (Model 3176B)
(Model 3176B1)
VALUE
44
.69 x 1.66
TAPPED HOLE AT CENTER TAPPED HOLE AT CENTER
UNITS
GRAMS
IN
10-32 1/4-28
ELECTRICAL CONNECTOR, AXIAL 2-PIN MILITARY Mil-C-5015, HERMETIC
MATERIAL CASE/CONNECTOR
ELEMENT TYPE
PERFORMANCE
SENSITIVITY, ± 5% [1]
RANGE FOR ± 5 VOLTS OUT
FREQUENCY RESPONSE, ± 10%
MOUNTED RESONANT FREQUENCY, TYP.
EQUIVALENT ELECTRICAL NOISE FLOOR, (RESOLUTION)
AMPLITUDE NON-LINEARITY (ZERO BASED BEST FIT ST.LINE METHOD) TRANSVERSE SENSITIVITY, MAX.
300 SERIES
PIEZOCERAMIC, PLANAR SHEAR
100 ±50
0.3 to 10,000
27
.00002
2.0
5
ST. STEEL
mV/G
G
Hz
kHz
G RMS
% F.S., MAX.
PERCENT
STRAIN SENSITIVITY
ENVIRONMENTAL
MAXIMUM VIBRATION
MAXIMUM SHOCK
TEMPERATURE RANGE
.0001
500
5000
-60 TO +250
G's PER MICROSTRAIN @ 250/µs
G's, RMS G's, PEAK
oF
ENVIRONMENTAL SEAL
ELECTRICAL
COMPLIANCE (SUPPLY) VOLTAGE RANGE [2]
EXCITATION CURRENT RANGEOUTPUT IMPEDANCE, NOM.
OUTPUT BIAS VOLTAGE, ± 1. VOLTS DISCHARGE TIME CONSTANT, MIN.
OUTPUT SIGNAL POLARITY FOR ACCELERATION TOWARD TOP POWER/SIGNAL GROUND to CASE ISOLATION, MIN.
ACCESSORIES PROVIDED
GLASS TO METAL/WELDED,HERMETIC
+20 to +30
2 to 20
200
13 .5
POSITIVE GOING
10
VDC
mA
OHMS
VDC SEC.
MEGOHMS
MODEL 3176B [1] MODEL 6200S MOUNTING STUD
MODEL 3176B1 [1] MODEL 6176 MOUNTING STUD
NOTES
[1] MEASURED AT 100 Hz, 1 G RMS. A CALIBRATION CERTIFICATE TRACEABLE TO NIST IS SUPPLIED WITH EACH INSTRUMENT.
[2] THE USE OF DYTRAN LIVM CURRENT SOURCE POWER UNITS IS RECOMMENDED. DO NOT CONNECT THIS INSTRUMENT TO
A SOURCE OF DC VOLTAGE WITHOUT CURRENT LIMITING PROTECTION, 20 mA MAX. TO DO SO WILL DESTROY THE INTERNAL AMPLIFIER AND VOID THE WARRANTY.