  • Lượt xem: 4472

  • No furnace installation or service work should be performed without doing a gas leak test and a Carbon Monoxide (CO) Test. Combustion Efficiency Analyzer Three Tools in One! The 708 is an affordable combustion efficiency analyzer, CO analyzer, and a differential thermometer for residential and light industrial applications.

    Measures CO, O2 and temperature
    Calculates CO2, efficiency, excess air and CO air free
    Selectable fuels: natural gas, light oil, heavy oil and LPG
    Pump driven for fast response
    Flue probe with built-in thermocouple
    IR printer port - use optional A740 Infrared Printer
    Soft carrying case
    Protective rubber boot

  • Tags: Bàn Map
Đơn vị tiền tệ
  • Số lượng:
  • Thành tiền
TPI-708C5 Kit
Includes TPI-708 and TPI-270
 
TPI-708A740 Kit
Includes TPI-708 and TPI-A740
 
TPI-708C7 Kit
Includes TPI-708, TPI-270 and TPI-A740
 
TPI-708C8 Kit
Includes TPI-708, TPI-620, TPI-A774, TPI-A605 two TPI-A776
 
TPI-708C10 Kit
Includes TPI-708, TPI-620, TPI-A740, two TPI-GK13M, two TPI-A605 and two TPI-A603
 
TPI-708C9 Kit
Includes TPI-708, TPI-270, TPI-A740, TPI-620, TPI-A774, two TPI-A605 and two TPI-A776
 
TPI-A740
  • Self test at power on
  • Adjustable contrast
  • Uses common thermal paper
  • Manual paper advance
 
TPI-270

APPLICATIONS

  • Thermocouples in furnace and gas appliances
  •  Heat anticipator current in thermostats
  •  Line voltages
  •  Control Voltages
  •  Flame safety control current
  •  Heating element resistance
  •  Compressor winding resistance
  •  Contractor and relay coil resistance
  •  Motor and compressor startup current
  •  Motor run and start capacitors
  •  Bar graph indicator of rapid fluctuations
  •  Continuity of wiring
  •  Measure frequency on control and line voltage
  •  Record minimum and maximum of measurements
  •  Measure temperature
  •  Measure true RMS of distorted or non-linear signals
  •  Measure line current
  •  Test continuity of circuit breakers and fuses
  •  Measure voltage of direct drive DC motors
  •  Measure power supply voltage
  •  Measure power supply current
  •  Non-contact Voltage Detection

SPECIFICATIONS

  • Auto/Manual

DISPLAY SPECIFICATIONS

  • 4,000 count
  • Analog bar graph

BASIC FEATURES

  • AC volts
  • DC volts
  • AC amps
  • DC Microamps (using the test leads)
  • Resistance
  • Diode test
  • Audible continuity

ADDITIONAL FEATURES

  • Frequency
  • Capacitance
  • Temperature
  • Non-Contact voltage detection
  • Data hold
  • Relative Mode
  • Min/max/peak
  • Peak hold
  • Sleep mode/Auto off

RANGE AND RESOLUTION

  • Basic DC Accuracy: .5%
  • DC Voltage (maximum): 600V
  • Resolution (maximum): 0.1mV
  • AC Voltage (Maximum): 600V
  • Resolution (maximum): .1mV
  • DC Amps (maximum): 400µA
  • Resolution (maximum): .01µA
  • AC Amps (maximum): 400mA
  • Resolution (Maximum): .01 A
  • Resistance (maximum): 40M
  • Resolution (maximum): 0.1
  • Frequency (maximum): 400MHz
  • Resolution (maximum): .001KHz
  • Capacitance (maximum): 40,000°F
  • Resolution (maximum): .001°F
  • Temperature (maximum): 1000°F

AGENCY APPROVAL

  • CE IEC 1010: CAT III 600V
  • cULus 3111: Pending
 TPI-620
Dual Input Digital Manometer in H20
Experienced Utility and HVAC troubleshooters choose

TPI for value and quality. Replace messy U-tubes and

expensive pressure gauges with TPI's 600 series

manometers. Isolating difficult pressure problems on

natural gas and propane systems has never been better.

Test for leaks in low-pressure gas systems with the

confidence of TPI products. Basic accuracy of ±0.5%

reading with .01 inH20.

SPECIFICATIONS

  • Auto Range: -15 to +48 in H2O
  • Accuracy: ± 0.5% of reading +5 digits
  • Resolution: .01 in H2O
  • Over Pressure: 500mBar
  • Power Supply: 9V
  • Relative Humidity: 0% to 80% (0° to + 40° C)
  • Operating Temp: 0° to +40° C
  • Storage Temp: -10° C to + 50° C
  • Auto Power Off: After 40 minutes

APPLICATIONS

  • Adjusting appliance regulators
  • Setting delivery pressures
  • Leakage "shut-in" tests
  • Regulator adjustments for pressure and lock-up tests
  • Test pressure switch operation on a 2-stage gas furnace in both positive and negative pressures
  • Static pressures in air ducts for air balancing
  • Check air filters by measuring pressure drop