DCV: 1000 V /± 0.09%+2 dgt
ACV: 1000 V /± 2%+3 dgt
DCA: 400mA /± 0.2%+2 dgt
ACA: 400mA /± 0.9%+2 dgt
R: 50 MΩ /± 0.9%+2 dgt
R: 50 MΩ /±0.9%+2 dgt
C: 9,999 µF /±(1.2%+2)
F: 100 kHz /±(0.1%+1)
T type K:-40.0 °C đến 537 °C (-40.0 °F đến 998 °F)
Điện áp thử: 50, 100, 250, 500, 1000 V
Giả đo điện trở cách điện: 2 GΩ
Kích thước: 203 x 100 x 50 mm
Trọng lượng: 624 g
Cấp bảo vệ: IP40
Phụ kiện: dây đo, đầu kẹp, hộp cứng, dây đo nhiệt độ kiểu K, 4 pin AA, HDSD, CD HDSD
Hãng sản xuất: Fluke
Xuất xứ: Mỹ
Bảo hành: 12 tháng
Specifications
Voltage DC
Maximum Voltage:
1000 V
Accuracy:
1577: ±(0.2%+2)
1587: ±(0.09%+2)
Maximum Resolution:
0.001V
Voltage AC
1577: ±(2%+3)
1587: ±(2%+3)
AC Bandwidth:
1587: 5kHz*
*with low pass filter; 3db @ 800 Hz
0.1 mV
Current DC
Maximum Amps:
400mA
Amps Accuracy:
1577: ±(1.0%+2)
1587: ±(0.2%+2)
0.01 mA
Current AC
1577: ±(2.0%+2)*
1587: ±(1.5%+2)*
* 1kHz bandwidth
Resistance
Maximum Resistance:
50 MΩ
1577: ±(1.2%+2)
1587: ±(0.9%+2)
0.1Ω
Capacitance(1587 only)
Maximum Capacitance:
9,999 µF
±(1.2%+2)
1 nF
Frequency (1587 only)
Maximum Frequency:
100 kHz
±(0.1%+1)
0.01 Hz
Temperature Measurement (1587 only)
-40.0 °C to 537 °C
-40.0 °F to 998 °F
excluding probe
Diode Test (1587 only)
Range:
6 V
Resolution:
1 mV
±(2 % + 1)
Insulation Test
Minimum Test Current @ 1kΩ/V:
1mA
Test Voltages:
1577:
500, 1000 V
1587:
50, 100, 250, 500, 1000 V
Maximum Resistance per Test Voltage:
50V:
100V:
250V:
500V:
1000V:
1577: 600 MΩ
1587: 2 GΩ
Maximum Resolution per Test Voltage:
0.01 MΩ
0.1 MΩ
Accuracy per Test Voltage:
±(3 % + 5)
±(1.5 % + 5)
1577: ±(2.0 % + 5)
1587: ±(1.5 % + 5)
1587: ±(1.5 % + 5) to 600 MΩ, ±(10 % + 3) above 600 MΩ
Environmental Specifications
Operating temperature
–20 °C to +55 °C
Storage temperature
-40°C to +60°C
Humidity (Without Condensation)
0% - 95% (10 °C – 30 °C)
0% - 75% (30 °C – 40 °C)
0% - 40% (40 °C – 55 °C)
Operating Altitude
2000 m
Safety Specifications
Overvoltage category
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
Agency Approvals
2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
Mechanical & General Specifications
Size
203 x 100 x 50 mm (with holster)
Weight
624 g
Warranty
Battery life Alkaline
Meter use:
1000 hours
Insulation test use:
Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
IP Rating
IP40