  • Lượt xem: 3948
  • They are extremely powerful and robust with a high-quality finish. The lockable doors protect the controls and burner against unauthorised use and the oil heating stations are not only easy to service, they also have a whole array of other service-friendly features.
  • Tags: Bàn Map
Đơn vị tiền tệ
  • Số lượng:
  • Thành tiền
  • Brand-name burner with high degree of efficiency
  • Single-chord system with automatic venting
  • Large-scale 300 W fuel preheating feature
  • Photocell flame monitor
  • High-performance heat exchanger
  • Fully-automatic operation with room air control
  • High-pressure radial fan for covering long distances with air transport hoses
  • Cold-proof up to temperatures of -20°C
  • Lockable doors for operational controls and burner
  • Protected control box with operational hours counter
  • Service-friendly construction due to removable side panels
  • Automatic fan with rotational direction check
  • Built-in circuit beaker
  • Summer-winter switch for ventilation operation without heating
  • Stainless steel skids
  • Fork lift slits
  • Suitable for fully-automatic operation with external thermostat
  • Two-stage model (optional)
  • Technical dataID 1000ID 1200ID 2000
    Air flow rate max. Stage 1 9,120 m³ 9,780 m³ 25.100 m³
    Stage 2 * 12,950 m³ 13,860 m³
    Air pressure max. Stage 1 480 Pa 540 Pa 300 Pa
    Stage 2 * 540 Pa 620 Pa
    Fan High-pressure radial High-pressure radial High-pressure radial
    Rated heat input max. Stage 1 150 kW 160 kW 375 kW
    Stage 2 * 200 kW 220 kW
    Heating capacity max. Stage 1 138 kW (118,659 kcal) 148 kW (127,257 kcal) 345 kW (296,647 kcal)
    Stage 2 * 184 kW (158,240 kcal) 203 kW (174,548 kcal)
    Sound level (distance 1 m) ** 74 dB (A) 74 dB (A) 75 dB (A)
    Temperature increase*** ∆T 57 °C 59 °C 55 °C
    Input voltage 400 V / 50 Hz 400 V / 50 Hz 400 V / 50 Hz
    Current consumption max. Stage 1 NS NS 29.5 A
    Stage 2 * 9.3 A 9.8 A
    Fuel Heating oil or diesel
    Fuel consumption max. Stage 1 NS NS 36.7 l/h
    Stage 2 * 19.5 l/h 20.9 l/h
    Outlet cone ø 550 mm ø 550 mm ø 3 x 500 mm
    Chimney connection ø 200 mm ø 200 mm ø 300 mm
    Thermostat connection standard standard standard
    Dimensions L x W x H 2,400 x 800 x 1,370 mm 2,400 x 800 x 1,370 mm 3,900 x 1,200 x 2,010 mm
    Mobility Fork lifter / crane
    Weight 480 kg 505 kg 1,050 kg
    Electricity supply Mains cable with 16 A CEE plug, 5-pole Mains cable with 16 A CEE plug, 5-pole 32 A CEE socket, 5-pole